The following settings are available on the Settings tab of a device.
We recommend that you define as many settings as possible in the root group settings so that you can inherit them to all other objects in the object hierarchy.
For device settings, you can also use multi-edit. This enables you to change the settings of many devices at the same time.
This documentation refers to an administrator that accesses the PRTG web interface on a master node. Other user accounts, interfaces, or failover nodes might not have all of the options in the way described here. In a cluster, note that failover nodes are read-only by default.
If the name contains angle brackets (<>), PRTG replaces them with braces ({}) for security reasons. For more information, see the Knowledge Base: What security features does PRTG include?
Monitoring Status
Select the monitoring status of the device:
Started: Monitor the device.
Paused: Pause monitoring for the device. All sensors on the device are in the Pausedstatus until you change this setting.
IP Version
Select the IP protocol that PRTG uses to connect to the device:
IPv4: Use IP version 4 for all requests to the device.
IPv6: Use IP version 6 for all requests to the device.
The setting is valid for all sensors that you create on the device.
IPv4 Address/DNS Name
This setting is only visible if you select IPv4 above. Enter the IP address or Domain Name System (DNS) name for the device. Most sensors that you create on this device inherit this setting and try to connect to this address for monitoring.
Some sensors have their own setting for the IP address/DNS name to which they connect.
IPv6 Address/DNS Name
This setting is only visible if you select IPv6 above. Enter the IP address or Domain Name System (DNS) name for the device. Most sensors that you create on this device inherit this setting and try to connect to this address for monitoring.
Some sensors have their own setting for the IP address/DNS name to which they connect.
This setting is for your information only. You cannot change it.
Tags
Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.
We recommend that you use the default value. You can also add additional tags.
It is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).
For performance reasons, it can take some minutes until you can filter for new tags that you added.
Priority
Select a priority for the device. This setting determines the position of the group in lists. The highest priority is at the top of a list. You can choose from the lowest priority () to the highest priority ().
Additional Device Information
Additional Device Information
Setting
Description
Device Icon
Select a device icon. PRTG shows it in the device tree.
Service URL
Specify a URL to open directly when you select Device Tools | Go to Service URLfrom the context menu of the device. For example, you can configure this option to open the address http://www.example.com/service.html. Enter a valid URL or leave the field empty.
No auto-discovery: Select this option if you only want to manually create devices and sensors.
Standard auto-discovery (recommended): Create a set of standard sensors for standard monitoring. This option works fine for most installations.
Detailed auto-discovery: Create all standard sensors and additional sensors from detailed variants of device templates. As a result, you might get many sensors. This option is suitable for small network segments and whenever you want to monitor the maximum number of sensors available.
Auto-discovery with specific device templates: Customize the auto-discovery and select or combine standard, detailed, and custom device templates. Select one or more templates from the Device Templates list.
Auto-discoveries can be resource intensive. They are primarily intended for devices on the same network as your probes.
Schedule
Select when PRTG runs the auto-discovery:
Once: Run the auto-discovery only once. PRTG adds new devices and sensors once. If you select this option, you must manually start the auto-discovery.
Hourly: Run the auto-discovery for new devices and sensors every 60 minutes. Use this option with caution. Frequent auto-discoveries might cause performance issues, in particular when PRTG scans large network segments every hour.
Daily: Run the auto-discovery for new devices and sensors every 24 hours. The first auto-discovery runs immediately. All other discoveries start at the time that you define in the Monitoring settings, section Auto-Discovery.
Weekly: Run the auto-discovery for new devices and sensors every 7 days. The first auto-discovery runs immediately. All other discoveries start at the time that you define in the Monitoring settings, section Auto-Discovery.
For performance reasons, PRTG sets Schedule to Once on all devices that the scheduled auto-discovery creates.
Device Templates
This setting is only visible if you select Auto-discovery with specific device templates above. Select one or more device templates by enabling a check box in front of the template name.
You can also select all items or cancel the selection by using the check box in the table header.
PRTG uses the device templates that you select for the auto-discovery on the device. Choose from:
ADSL
Amazon CloudWatch
Buffalo TeraStation NAS
Cisco ASA VPN
Cisco Device (Generic)
Dell EqualLogic
Dell MDi Disk
DNS Server
Environment Jacarta
Environment Poseidon
FTP Server
Generic Device (Ping Only)
Generic Device (SNMP Enabled)
Generic Device (SNMP Enabled, Detailed)
HTTP Web Server
Hyper-V Host Server
IPMI-enabled Device
Juniper NS Device
Linux/UNIX Device (SNMP or SSH Enabled)
Mail Server (Generic)
Mail Server (MS Exchange)
Microsoft SharePoint 2010
NAS LenovoEMC
NAS QNAP
NAS Synology
NetApp
NTP Server
Printer (HP)
Printer (Generic)
RDP Server
RMON-compatible Device
Server (Cisco UCS)
Server (Compaq/HP Agents)
Server (Dell)
Server (Fujitsu)
Server (IBM)
SonicWall
SSL Security Check
Switch (Cisco Catalyst)
Switch (Cisco IOS Based)
Switch (HP Procurve)
UNIX/Linux Device
UPS Health (APC)
UPS Health (Generic)
UPS Health (Liebert)
VMware ESXi / vCenter Server
Web Server
Windows (Detailed via WMI)
Windows (via Remote PowerShell)
Windows (via WMI)
Windows IIS (via SNMP)
XenServer Hosts
XenServer Virtual Machines
Once the auto-discovery is finished, PRTG creates a new ticket and lists the device templates that it used to create new sensors.
Inherited Settings
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
If you want to use Geo Maps, enter a location in the first line. Geographical maps then display objects like devices or groups with a status icon using a color code similar to the sensor status icons (green–yellow–orange–red). You can enter a full postal address, city and country only, or latitude and longitude. It is possible to enter any text before, between, and after the coordinates, as PRTG automatically parses latitude and longitude, for example, enter 49.452778 11.077778, or enter 49.452778 any 11.077778 text.
A minus sign (-) in the first line hides an object from a geographical map. In this case, you can enter location information in line two and following.
You can define a specific label for each location. Enter a string denoting the label in the first line and provide the coordinates in the second line. This geographical marker then shows the object with the label in the geographical map.
The preview map always has a road map layout regardless of the map layout you set in User Interface.
Enter the domain or computer name of the user account with which you want to access the Windows system. PRTG uses this account for Windows Management Instrumentation (WMI) sensors and other Windows sensors.
If you want to use a Windows local user account on the target device, enter the computer name. If you want to use a Windows domain user account (recommended), enter the domain name. PRTG automatically adds a prefix to use the NT LAN Manager (NTLM) protocol if you do not explicitly define it. Do not leave this field empty.
User Name
Enter the user name for access to the Windows system. Usually, you use credentials with administrator rights.
Password
Enter the password for access to the Windows system. Usually, you use credentials with administrator rights.
Credentials for Linux/Solaris/macOS (SSH/WBEM) Systems
Credentials for Linux/Solaris/macOS (SSH/WBEM) Systems
Setting
Description
User Name
Enter the user name for access to the Linux/Solaris/macOS system via Secure Shell (SSH) and Web-based Enterprise Management (WBEM). Usually, you use credentials with administrator rights.
Authentication Method
Select the authentication method for the login:
Password: Provide the password for the login.
Private key: Provide an RSA private key for authentication.
PRTG can only handle keys in the OpenSSH format that are not encrypted. You cannot use password-protected keys.
PRTG only supports RSA keys. It does not support DSA keys.
This setting is only visible if you select Password above. Enter a password for access to the Linux/Solaris/macOS system via SSH and WBEM. Usually, you use credentials with administrator rights.
Private Key
This setting is only visible if you select Private key above. Paste the entire RSA private key, including the BEGIN and END lines. Make sure that a corresponding public key exists on the target device.
PRTG can only handle keys in the OpenSSH format that are not encrypted. You cannot use password-protected keys.
PRTG only supports RSA keys. It does not support DSA keys.
If you do not insert a private key for the first time but if you want to change the private key, you need to restart the PRTG core server service for the private key change to take effect.
WBEM Protocol
Select the protocol that you want to use for the connection to the system via WBEM:
HTTP: Use an unsecure connection for WBEM.
HTTPS (default): Use a Secure Sockets Layer (SSL)/Transport Layer Security (TLS) secured connection for WBEM.
This setting is only relevant if you use WBEM sensors.
WBEM Port
Select if you want to use one of the default ports for the connection to the system via WBEM or if you want to set a custom port:
Default: Use one of the default ports. The default port for unsecure connections is 5988 and the default port for secure connections is 5989.
Custom: Use a custom port.
This setting is only relevant if you use WBEM sensors.
Custom WBEM Port
This setting is only visible if you select Custom above. Enter a custom WBEM port. Enter an integer.
SSH Port
Enter the port for SSH connections. Enter an integer. The default port is 22.
By default, PRTG automatically uses this setting for all SSH sensors unless you define a different port number in the sensor settings.
SSH Rights Elevation
Select the rights that you want to use to run the command on the target system:
Run the command as the connecting user (default): Use the rights of the user who establishes the SSH connection.
Run the command as a different user using 'sudo' (with password): Use the rights of a different user with a password required for sudo to run commands on the target system, for example, as a root user.
Run the command as a different user using 'sudo' (without password): Use the rights of a different user without a password required for sudo to run commands on the target system, for example, as a root user.
Run the command as a different user using 'su': Use the rights of a different user with su to run commands on the target system.
Target System User Name
This setting is only visible if you select an option that includes sudo or su above. Enter a user name to run the specified command on the target system as a different user than the root user. If you leave this field empty, you run the command as a root user. Make sure that you set the Linux password even if you use a public key or a private key for authentication. This is not necessary if the user is allowed to run the command without a password.
Password
This setting is only visible if you select an option that includes sudo or su with password above. Enter the password to run the sudo command or the su command.
Default (recommended): This is the default connection mode for SSH sensors. It provides the best performance and security.
Compatibility mode (deprecated): Use this only if the default connection mode does not work on the target system. The compatibility mode is the connection mode that PRTG used in previous versions and it is deprecated.
We strongly recommend that you use the default connection mode.
You can also individually select the connection mode for each SSH sensor in the sensor settings.
Enter the user name for access to VMware ESXi, vCenter Server, or Citrix XenServer. Usually, you use credentials with administrator rights.
Password
Enter the password for access to VMware ESXi, vCenter Server, or Citrix XenServer. Usually, you use credentials with administrator rights.
Single sign-on (SSO) passwords for vSphere do not support special characters. For details, see the VMware sensors sections.
VMware Protocol
Select the protocol for the connection to VMware ESXi, vCenter Server, or Citrix XenServer:
HTTPS (recommended): Use a Secure Sockets Layer (SSL)/Transport Layer Security (TLS) secured connection.
HTTP: Use an unsecure connection.
Session Handling
Select if you want to reuse a session for VMware sensors:
Reuse a session for multiple scans (recommended): Select this option if you want a VMware sensor to reuse a single session for multiple sensor scans to query data. With this option, the sensor does not need to log in and out for each sensor scan. We recommend that you use this option because it reduces network load and log entries on the target device. This can increase performance.
Create a new session for each scan: If you select this option, PRTG does not reuse a session and a VMware sensor has to log in and out for each sensor scan. This can decrease performance.
Select the Simple Network Management Protocol (SNMP) version for the connection to the target SNMP device:
SNMP v1: Use SNMP v1 for the connection. SNMP v1 only offers clear-text data transmission. SNMP v1 does not support 64-bit counters. This might result in invalid data when you monitor traffic via SNMP.
SNMP v2c (recommended): Use SNMP v2c for the connection. SNMP v2c also only offers clear-text data transmission but it supports 64-bit counters.
SNMP v3: Use SNMP v3 for the connection. SNMP v3 provides secure authentication and data encryption. SNMP v3 has performance limitations because of the use of encryption. The main limiting factor is CPU power. Also keep in mind that SNMP v3, unlike SNMP v1 and v2c, does not scale with more CPU power. Because of this limitation, PRTG can only handle a limited number of requests per second so that you can use only a limited number of sensors using SNMP v3. If you see an increase in Interval Delay or Open Requests with the Probe Health sensor, distribute the load over multiple probes. SNMP v1 and SNMP v2c do not have this limitation.
Community String
This setting is only visible if you select SNMP v1 or SNMP v2c (recommended) above. Enter the community string of your device. This is like a clear-text password for simple authentication.
We recommend that you use the default value.
Authentication Method
This setting is only visible if you select SNMP v3 above. Select the authentication method:
MD5: Use message-digest algorithm 5 (MD5) for authentication.
SHA: Use Secure Hash Algorithm (SHA) for authentication.
SHA-224: Use SHA-224 for authentication.
SHA-256: Use SHA-256 for authentication.
SHA-384: Use SHA-384 for authentication.
SHA-512: Use SHA-512 for authentication.
If you do not want to use authentication but you need SNMP v3, for example, because your device requires context, you can leave the Password field empty. In this case, PRTG uses SNMP_SEC_LEVEL_NOAUTH and it entirely deactivates authentication.
The authentication method you select must match the authentication method of your device.
User Name
This setting is only visible if you select SNMP v3 above. Enter the user name for access to the target SNMP device.
The user name that you enter must match the user name of your device.
Password
This setting is only visible if you select SNMP v3 above. Enter the password for access to the target SNMP device.
The password that you enter must match the password of your device.
Encryption Type
This setting is only visible if you select SNMP v3 above. Select an encryption type:
DES: Use Data Encryption Standard (DES) as the encryption algorithm.
AES: Use Advanced Encryption Standard (AES) as the encryption algorithm.
AES-192: Use AES-192 as the encryption algorithm.
AES-256: Use AES-256 as the encryption algorithm.
The encryption type that you select must match the encryption type of your device.
Encryption Key
This setting is only visible if you select SNMP v3 above. Enter an encryption key. If you provide a key, PRTG encrypts SNMP data packets with the encryption algorithm that you selected above. Enter a string or leave the field empty.
The encryption key that you enter must match the encryption key of your device. If the encryption keys do not match, you do not get an error message.
Context Name
This setting is only visible if you select SNMP v3 above. Enter a context name only if the configuration of the device requires it. Context is a collection of management information that is accessible by an SNMP device. Enter a string.
SNMP Port
Enter the port for the connection to the SNMP target device. Enter an integer. The default port is 161.
We recommend that you use the default value.
Timeout (Sec.)
Enter a timeout in seconds for the request. Enter an integer. The maximum timeout value is 300 seconds (5 minutes).
Select the port that PRTG uses for connections to the monitored databases:
Default (recommended): PRTG automatically determines the type of the database and uses the corresponding default port to connect. PRTG uses the following default ports:
Microsoft SQL: 1433
MySQL: 3306
Oracle SQL: 1521
PostgreSQL: 5432
Custom port for all database sensors: Select this option if your database management systems do not use the default ports. Enter a custom port for database connections below.
Custom Port
Enter a custom port for database connections. Enter an integer.
PRTG uses this custom port for all database sensors and for connections to all your databases.
Authentication Method
Select the authentication method for the connection to the Structured Query Language (SQL) database:
Windows authentication with impersonation: PRTG uses the Windows credentials that you define in settings that are higher in the object hierarchy, for example, in the settings of the parent device; for the database connection. The user whose credentials PRTG uses needs to have permission to log in to the probe system with a database sensor. This is necessary for the impersonation.
SQL server authentication: Use explicit credentials for database connections. Enter a user name and password below.
User Name
This setting is only visible if you select SQL server authentication above. Enter the user name for the database connection.
Password
This setting is only visible if you select SQL server authentication above. Enter the password for the database connection.
Timeout (Sec.)
Enter a timeout in seconds for the request. Enter an integer. The maximum timeout value is 300 seconds (5 minutes).
Enter a description for Placeholder 1, for example information about the purpose or content of the placeholder.
Placeholder 1
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder1 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 2 Description
Enter a description for Placeholder 2, for example information about the purpose or content of the placeholder.
Placeholder 2
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder2 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 3 Description
Enter a description for Placeholder 3, for example information about the purpose or content of the placeholder.
Placeholder 3
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder3 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 4 Description
Enter a description for Placeholder 4, for example information about the purpose or content of the placeholder.
Placeholder 4
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder4 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 5 Description
Enter a description for Placeholder 5, for example information about the purpose or content of the placeholder.
Placeholder 5
Enter a value for the placeholder. PRTG inserts the value for the script execution if you add %scriptplaceholder5 in the argument list. PRTG does not display the value in the sensor log or the sensor's settings.
Enter the user name for access to the HPE 3PAR system.
Password
Enter the password for access to the HPE 3PAR system.
Protocol
Select the protocol that you want to use for the connection to the HPE 3PAR system:
HTTPS (default): Use a Secure Sockets Layer (SSL)/Transport Layer Security (TLS) secured connection.
HTTP: Use an unsecure connection.
WSAPI Port
Enter the Web Services API (WSAPI) port for the connection to the HPE 3PAR system. The default port for secure connections is 8080 and the default port for unsecure connections is 8008.
Select the authentication method for access to the server. Choose between:
None (default): Use no authentication.
Basic authentication: Use basic authentication.
Bearer authentication: Use an OAuth2 bearer token.
User Name
This setting is only visible if you select Basic authentication above. Enter the user name for access to the server.
Password
This setting is only visible if you select Basic authentication above. Enter the password for access to the server.
Bearer Token
This setting is only visible if you select Bearer authentication above. Enter a bearer token for access to the server.
Placeholder 1 Description
Enter a description for Placeholder 1, for example information about the purpose or content of the placeholder.
Placeholder 1
Enter a value for the placeholder. PRTG inserts the value for the HTTP request if you add %httpplaceholder1 in the URL, POST Body, and Custom Header fields of the HTTP v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 2 Description
Enter a description for Placeholder 2, for example information about the purpose or content of the placeholder.
Placeholder 2
Enter a value for the placeholder. PRTG inserts the value for the HTTP request if you add %httpplaceholder2 in the URL, POST Body, and Custom Header fields of the HTTP v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 3 Description
Enter a description for Placeholder 3, for example information about the purpose or content of the placeholder.
Placeholder 3
Enter a value for the placeholder. PRTG inserts the value for the HTTP request if you add %httpplaceholder3 in the URL, POST Body, and Custom Header fields of the HTTP v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 4 Description
Enter a description for Placeholder 4, for example information about the purpose or content of the placeholder.
Placeholder 4
Enter a value for the placeholder. PRTG inserts the value for the HTTP request if you add %httpplaceholder4 in the URL, POST Body, and Custom Header fields of the HTTP v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 5 Description
Enter a description for Placeholder 5, for example information about the purpose or content of the placeholder.
Placeholder 5
Enter a value for the placeholder. PRTG inserts the value for the HTTP request if you add %httpplaceholder5 in the URL, POST Body, and Custom Header fields of the HTTP v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
Select if you want to connect without credentials or define credentials for access to the MQTT broker.
None (default): Connect without credentials.
User name and password: Define credentials for the connection.
User Name
This setting is only visible if you select User name and password above. Enter the user name for access to the Message Queue Telemetry Transport (MQTT) broker.
Password
This setting is only visible if you select User name and password above. Enter the password for access to the MQTT broker.
Port
Enter the port for the connection to the MQTT broker. The default port for secure connections is 8883 and the default port for unsecure connections is 1883.
Transport-Level Security
Select if you want to use a Secure Sockets Layer (SSL)/Transport Layer Security (TLS) secured connection:
Do not use transport-level security: Establish the connection without connection security.
Use transport-level security: Establish the connection with the strongest SSL/TLS method that the target device provides.
Server Authentication
This setting is only visible if you select Use transport-level security above. Select if you want to use a certificate for server authentication.
Disable (default): Do not use a certificate for server authentication.
Enable: Use a certificate for server authentication.
CA Certificate
This setting is only visible if you enable Server Authentication above. Paste the certificate authority (CA) certificate for the verification of the MQTT broker.
The certificate must be in Privacy-Enhanced Mail (PEM) format.
Client Authentication
This setting is only visible if you select Use transport-level security above. Select if you want to use a certificate for client authentication.
Disable (default): Do not use a certificate for client authentication.
Enable: Use a certificate for client authentication.
Client Certificate
This setting is only visible if you enable Client Authentication above. Paste the certificate that you created for authenticating the sensor against the MQTT broker.
The certificate must be in PEM format.
Client Key
This setting is only visible if you enable Client Authentication above. Enter the client key for access to the MQTT broker.
The client key must be in PEM format and it must be encrypted using the Client Key Password.
Client Key Password
This setting is only visible if you enable Client Authentication above. Enter the password for the client key.
Enter the port for the connection to the OPC Unified Architecture (OPC UA) server. The default port for secure connections is 4840.
Server Path
Enter the path of the OPC UA server endpoint if you run more than one server under the same IP address or DNS name.
Security Mode
Select if you want to use encryption:
None (default): Do not use encryption.
Sign: Sign messages between the sensor and the OPC UA server.
Sign & Encrypt: Sign and encrypt messages between the sensor and the OPC UA server.
Security Policy
This setting is only visible if you select Sign or Sign & Encrypt above. Select if you want to use a security policy and define which policy you want to use:
None (default): Do not use a security policy.
Basic256Sha256: Use the Basic256Sha256 security policy.
Basic256: Use the Basic256 security policy.
Client Certificate
This setting is only visible if you select Sign or Sign & Encrypt above. Enter the certificate that you created for authenticating the sensor against the OPC UA server.
The certificate must meet the following requirements:
The key size must be 2048-bit or 4096-bit.
The secure hash algorithm must be SHA256.
DataEncipherment must be part of the KeyUsage certificate extension.
A uniform resource indicator (URI) must be set in subjectAltName.
The certificate must be in Privacy-Enhanced Mail (PEM) format.
Client Key
This setting is only visible if you select Sign or Sign & Encrypt above. Enter the client key for access to the OPC UA server.
The client key must be in PEM format and it must be encrypted using the Client Key Password.
Client Key Password
This setting is only visible if you select Sign or Sign & Encrypt above. Enter the password for the client key.
Authentication Method
Select if you want to connect without credentials or define credentials for access to the OPC UA server:
Anonymous (default): Connect without credentials.
User name and password: Define credentials for the connection.
Most OPC UA servers do not support User name and password authentication without a client certificate. To use User name and password authentication, select Sign or Sign & Encryptunder Security Mode and Basic256Sha256 or Basic256 under Security Policy and enter the Client Certificate, Client Key, and Client Key Password that you want to use.
If you select None (default) under Security Mode and use User name and password authentication, PRTG sends the unencrypted password to the OPC UA server.
User Name
This setting is only visible if you select User name and password above. Enter the user name for access to the OPC UA server.
Password
This setting is only visible if you select User name and password above. Enter the password for access to the OPC UA server.
Select if you want to connect without credentials or define credentials for access to the Orchestra platform:
None (default): Connect without credentials.
User name and password: Define credentials for the connection.
User Name
This setting is only visible if you select User name and password above. Enter the user name for access to the Orchestra platform.
Password
This setting is only visible if you select User name and password above. Enter the password for access to the Orchestra platform.
Timeout (Sec.)
Enter a timeout in seconds for the request. Enter an integer. The maximum timeout value is 300 seconds (5 minutes).
Port
Enter the port for the connection to the Orchestra platform. The default port for secure connections is 8443 and the default port for unsecure connections is 8019.
Protocol
Select the protocol that you want to use for the connection to the Orchestra platform:
HTTPS (default): Use a Secure Sockets Layer (SSL)/Transport Layer Security (TLS) secured connection.
Select the authentication method for access to the Representational State Transfer (REST)application programming interface (API):
None (default): Use no authentication.
Basic authentication: Use basic authentication.
Bearer authentication: Use an OAuth2 bearer token.
User Name
This setting is only visible if you select Basic authentication above. Enter the user name for access to the REST API.
Password
This setting is only visible if you select Basic authentication above. Enter the password for access to the REST API.
Bearer Token
This setting is only visible if you select Bearer authentication above. Enter a bearer token for access to the REST API.
Placeholder 1 Description
Enter a description for Placeholder 1, for example information about the purpose or content of the placeholder.
Placeholder 1
Enter a value for the placeholder. PRTG inserts the value for the REST API request if you add %restplaceholder1 in the Request URL, POST Body, and Custom Headers fields of the REST Custom v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 2 Description
Enter a description for Placeholder 2, for example information about the purpose or content of the placeholder.
Placeholder 2
Enter a value for the placeholder. PRTG inserts the value for the REST API request if you add %restplaceholder2 in the Request URL, POST Body, and Custom Headers fields of the REST Custom v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 3 Description
Enter a description for Placeholder 3, for example information about the purpose or content of the placeholder.
Placeholder 3
Enter a value for the placeholder. PRTG inserts the value for the REST API request if you add %restplaceholder3 in the Request URL, POST Body, and Custom Headers fields of the REST Custom v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 4 Description
Enter a description for Placeholder 4, for example information about the purpose or content of the placeholder.
Placeholder 4
Enter a value for the placeholder. PRTG inserts the value for the REST API request if you add %restplaceholder4 in the Request URL, POST Body, and Custom Headers fields of the REST Custom v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
Placeholder 5 Description
Enter a description for Placeholder 5, for example information about the purpose or content of the placeholder.
Placeholder 5
Enter a value for the placeholder. PRTG inserts the value for the REST API request if you add %restplaceholder5 in the Request URL, POST Body, and Custom Headers fields of the REST Custom v2 sensor. PRTG does not display the value in the sensor log or the sensor's settings.
If you experience problems when you monitor via Windows sensors, use the following compatibility options for troubleshooting.
Windows Compatibility Options
Setting
Description
Preferred Data Source
This setting only applies to hybrid sensors that use both performance counters and Windows Management Instrumentation (WMI). The setting does not apply to other sensors.
Define the method that Windows sensors use to query data:
Performance counters and WMI as fallback: Try to query data via performance counters. If this is not possible, establish a connection via WMI.
Performance counters only: Query data via performance counters only. If this is not possible, the sensor returns no data.
WMI only (recommended): Query data via WMI only. If this is not possible, the sensor returns no data. We recommend that you use this option.
Timeout Method
Select the time that the sensor waits for the return of the WMI query before the sensor cancels the query and shows an error message:
Use 1.5× scanning interval (recommended): Multiply the scanning interval of the sensor by 1.5 and use the resulting value.
Set manually: Manually enter a timeout value.
We recommend that you use the default value.
If you experience ongoing timeout errors, try increasing the timeout value.
Timeout (Sec.)
This setting is only visible if you select Set manually above. Enter the time the sensor waits for the return of its WMI query before it cancels it and shows an error message. Enter an integer. The maximum timeout value is 900 seconds (15 minutes).
If you experience problems when you monitor via Simple Network Management Protocol (SNMP) sensors, use the following compatibility options for troubleshooting.
SNMP Compatibility Options
Setting
Description
SNMP Delay (ms)
Enter the time in milliseconds (ms) that PRTG waits between two SNMP requests. This can increase device compatibility. Enter an integer. You can define a delay between 0 and 100. PRTG does not support higher delays.
We recommend that you use the default value.
If you experience SNMP connection failures, try increasing the delay.
Failed Requests
Select if an SNMP sensor tries again after a request fails:
Retry (recommended): Try again if an SNMP request fails. This can prevent false error messages because of temporary timeout failures.
Do not retry: Do not retry if an SNMP request fails. If you select this option, an SNMP sensor shows a Down status earlier.
Overflow Values
Select how PRTG handles overflow values. Some devices do not correctly handle internal buffer overflows. This can cause false peaks.
Ignore (default): Ignore overflow values and do not include them in the monitoring data. We recommend that you use this option.
Handle overflow values as valid results: Regard all overflow values as regular data and include them in the monitoring data.
If you experience problems because of strange peaks in your data graphs, change this option. Peaks might indicate that the target device resets counters without an overflow. PRTG interprets such behavior as overflow that results in data peaks. Select the option Ignore (default) in this case. For more details, see the Knowledge Base: What is the Overflow Values setting in the SNMP Compatibility Options?
Zero Values
Select how PRTG handles zero values. Some devices send incorrect zero values. This can cause false peaks.
Ignore (recommended): Ignore zero values and do not include them in the monitoring data. We recommend that you use this option. If you experience problems, try changing this option.
Handle zero values as valid results for delta sensors: Regard all zero values as regular data and include them in the monitoring data.
32-bit/64-bit Counters
Select the type of traffic counters that PRTG searches for on a device:
Use 64-bit counters if available (recommended): The interface scan uses 64-bit traffic counters, if available. This can avoid buffer overflows in the devices
We recommend that you use the default value. If you experience problems, try changing this option.
Use 32-bit counters only: The interface scan always uses 32-bit traffic counters, even if 64-bit counters are available. This can make monitoring more reliable for some devices.
Request Mode
Select the request method that PRTG uses for SNMP sensors:
Use multi get (recommended): Bundle multiple SNMP requests into one request. We recommend that you use this option. If you experience problems, try changing this option.
Use single get: Use one request for each SNMP value. This can increase compatibility with older devices.
PRTG uses paging for SNMP requests. This means that if a sensor has to query more than 20 object identifiers (OID), it automatically polls the OIDs in packages of 20 OIDs each.
Walk Mode
Select the kind of SNMP walk that PRTG uses for SNMP sensors:
Use GETBULK requests (recommended): Request the next x OIDs in one SNMP request. The default value is 10. It is dynamic based on the response size. This option only works with devices that support SNMP as of version v2c. Make sure that you set the correct SNMP Version in the Credentials for SNMP Devices settings of the parent device or inherit it from objects that are higher in the object hierarchy.
Use GETNEXT requests: Request one OID at a time. This can increase compatibility with older devices or with devices that have insufficient SNMP BULKWALK support.
Port Name Template
Select how PRTG displays the name of SNMP sensors. Enter a template that uses several variables. When you add new sensors, PRTG scans the interface for available counters at certain OIDs. At each OID, several fields with interface descriptions are usually available. They are different for every device and OID. PRTG uses the information in these fields to name the sensors. If a field is empty or if it is not available, PRTG adds an empty string to the name. By default, the port name template is ([port]) [ifalias] [ifsensor], which creates a name like (001) Ethernet1 Traffic. You can use and combine any field names that are available at an OID of your device, for example:
[port]: The port number of the monitored interface.
[ifalias]: The 'alias' name for the monitored interface as specified by a network manager, providing a non-volatile handling.
[ifname]: The textual name of the monitored interface as assigned by the local device.
[ifdescr]: A textual string containing information about the target device or interface, for example, manufacturer, product name, or version.
[ifspeed]: An estimate of the monitored interface's current bandwidth (Kbit/s).
[ifsensor]: The type of the sensor, this is Traffic or RMON. This helps to differentiate between SNMP Traffic and SNMP RMON sensors.
Select how PRTG reacts if you change the names of ports in your physical device (for example, a switch or router):
Keep port names (use this if you edit the names in PRTG): Do not automatically adjust sensor names. This is the best option if you want to manually change names in PRTG.
Automatically update sensor names if port names change in the device: If PRTG detects port name changes in your physical device, it tries to automatically adjust the sensor names accordingly.
Select the field that PRTG uses for SNMP interface identification:
Automatic identification (recommended): Try the ifAlias field first to identify an SNMP interface and then try ifDescr. PRTG does not automatically try ifName.
Use ifAlias: For most devices, ifAlias is the best field to use for unique interface names.
Use ifDescr: Use this option if the port order of your device changes after a restart, and if no ifAlias field is available. For example, this is the best option for Cisco ASA devices. If you use this option, it is important that your device returns unique interface names in the ifDescr field.
Use ifName: You can also use this option if no unique ifAlias is available. If you use this option, it is important that your device returns unique interface names in the ifName field.
Do not update ports: Use this option to disable the automatic port identification.
The proxy settings determine how a sensor connects to a URL. You can enter data for an HTTP proxy server that sensors use when they connect via HTTP or HTTPS.
This setting only applies to HTTP sensors and how they monitor. To change the proxy settings for the PRTG core server, see section Core & Probes.
The SSL Certificate sensor and the SSL Security Check sensor do not support HTTP proxies but you can configure connections via SOCKS proxies in the sensors' settings:
Proxy Settings for HTTP Sensors
Setting
Description
IP Address/DNS Name
Enter the IP address or Domain Name System (DNS) name of the proxy server. If you leave this field empty, HTTP sensors do not use a proxy.
Port
Enter the port number of the proxy. The default port is 8080. Enter an integer.
User Name
If the proxy requires authentication, enter the user name for the proxy login.
Only basic authentication is available. Enter a string or leave the field empty.
Password
If the proxy requires authentication, enter the password for the proxy login.
Only basic authentication is available. Enter a string or leave the field empty.
Select a scanning interval from the dropdown list. The scanning interval determines the amount of time that the sensor waits between two scans. Choose from:
30 seconds
60 seconds
5 minutes
10 minutes
15 minutes
30 minutes
1 hour
4 hours
6 hours
12 hours
24 hours
You can change the available intervals in the system administration of PRTG Network Monitor.
If a Sensor Query Fails
Select the number of scanning intervals that the sensor has time to reach and to check a device again if a sensor query fails. Depending on the option that you select, the sensor can try to reach and to check a device again several times before the sensor shows the Downstatus. This can avoid false alarms if the target device only has temporary issues. For previous scanning intervals with failed requests, the sensor shows the Warning status. Choose from:
Set sensor to down status immediately: Set the sensor to the Down status immediately after the first request fails.
Set sensor to warning status for 1 interval, then set to down status (recommended): Set the sensor to the Warning status after the first request fails. If the second request also fails, the sensor shows the Down status.
Set sensor to warning status for 2 intervals, then set to down status: Set the sensor to the Down status only after the third request fails.
Set sensor to warning status for 3 intervals, then set to down status: Set the sensor to the Down status only after the fourth request fails.
Set sensor to warning status for 4 intervals, then set to down status: Set the sensor to the Down status only after the fifth request fails.
Set sensor to warning status for 5 intervals, then set to down status: Set the sensor to the Down status only after the sixth request fails.
Sensors that monitor via Windows Management Instrumentation (WMI) always wait at least one scanning interval before they show the Down status. It is not possible to immediately set a WMI sensor to the Down status, so the first option does not apply to these sensors. All other options can apply.
If you define error limits for a sensor's channels, the sensor immediately shows the Down status. None of the interval options apply.
If a channel uses lookup values, the sensor immediately shows the Down status. None of the interval options apply.
Select a schedule from the list. You can use schedules to monitor during a certain time span (days or hours) every week. Choose from:
None
Saturdays
Sundays
Weekdays
Weekdays Eight-To-Eight (08:00 - 20:00)
Weekdays Nights (17:00 - 09:00)
Weekdays Nights (20:00 - 08:00)
Weekdays Nine-To-Five (09:00 - 17:00)
Weekends
You can create schedules, edit schedules, or pause monitoring for a specific time span. For more information, see section Schedules.
Maintenance Window
Select if you want to set up a one-time maintenance window. During a maintenance window, monitoring stops for the selected object and all child objects. They show the Paused status instead. Choose between:
Do not set up a one-time maintenance window: Do not set up a one-time maintenance window. Monitoring is always active.
Set up a one-time maintenance window: Set up a one-time maintenance window and pause monitoring. You can define a time span for the pause below.
To cancel an active maintenance window before the defined end date, change the time entry under Maintenance Ends to a date in the past.
Maintenance Begins
Select if you want to set up a one-time maintenance window. During a maintenance window, monitoring stops for the selected object and all child objects. They show the Paused status instead. Choose between:
Do not set up a one-time maintenance window: Do not set up a one-time maintenance window. Monitoring is always active.
Set up a one-time maintenance window: Set up a one-time maintenance window and pause monitoring. You can define a time span for the pause below.
Maintenance Ends
This setting is only visible if you enable Set up a one-time maintenance window above. Use the date time picker to enter the start date and time of the one-time maintenance window.
Dependency Type
Select a dependency type. You can use dependencies to pause monitoring for an object depending on the status of a different object. You can choose from:
Use parent: Use the dependency type of the parent object.
Select a sensor: Use the dependency type of the parent object. Additionally, pause the current object if a specific sensor is in the Down status or in the Paused status because of another dependency.
You do not trigger a status change by dependency if you manually pause a master object or if you pause it by schedule.
To test your dependencies, select Simulate Error Status from the context menu of an object that other objects depend on. A few seconds later, all dependent objects are paused. You can check all dependencies under Devices | Dependencies in the main menu bar.
Dependency
This setting is only visible if you enable Select a sensor above. Click and use the object selector to select a sensor on which the current object will depend.
Dependency Delay (Sec.)
This setting is only visible if you select Select a sensor above. Define a time span in seconds for the dependency delay.
After the master sensor for this dependency returns to the Up status, PRTG additionally delays the monitoring of the dependent objects by the time span you define. This can prevent false alarms, for example, after a server restart or to give systems more time for all services to start. Enter an integer.
Select the user groups that have access to the object. You see a table with user groups and group access rights. The table contains all user groups in your setup. For each user group, you can choose from the following group access rights:
Inherited: Inherit the access rights settings of the parent object.
No access: Users in this user group cannot see or edit the object. The object neither shows up in lists nor in the device tree. There is one exception: If a user in this user group has access to a child object, the parent object is visible in the device tree but users in this user group cannot access it.
Read access: Users in this group can see the object and view its monitoring results. They cannot edit any settings.
Write access: Users in this group can see the object, view its monitoring results, and edit its settings. They cannot edit its access rights settings.
Full access: Users in this group can see the object, view its monitoring results, edit its settings, and edit its access rights settings.
To automatically set all child objects to inherit this object's access rights, enable the Revert access rights of child objects to "inherited" option.
Enabled: Activates the unusual detection for this object and, by default, for all objects underneath in the object hierarchy. Sensors that are affected by this setting show the Unusual status if PRTG detects unusual activity.
Disabled: Does not activate the unusual detection. PRTG ignores unusual values for sensors that are affected by this setting. These sensors do not show the Unusual status.
You can configure the behavior of the unusual detection or completely disable it in the system settings.
Similar Sensors Detection
Select if you want to activate the similar sensors analysis:
Enabled: Activates the similar sensors detection for this object and, by default, for all objects underneath in the object hierarchy. PRTG considers all sensors that are affected by this setting during the similarity analysis.
Disabled: Does not activate the similar sensors detection. PRTG does not consider sensors that are affected by this setting during the similarity analysis.
You can configure the depth of the analysis of the similar sensors detection or completely disable it in the system settings.
System Information
Select if you want to retrieve and show system information for your devices:
Enabled: Activates the system information feature for this object and, by default, for all objects underneath in the hierarchy.
Disabled: Does not activate the system information feature.
The System Information feature is enabled by default. To retrieve the data, PRTG automatically uses the credentials for Windows systems and the credentials for SNMP devices that you entered in the device settings or that the device inherits from a parent object like the root group. Consider this when you monitor devices that are outside of your local network, especially when you use SNMP v1 or SNMP v2c, which do not provide encryption.
This setting is not available on the hosted probe of a PRTG Hosted Monitor instance.
Save your settings. If you change tabs or use the main menu without saving, all changes to the settings are lost.